Weighing Instruments & Parts · T6X
Weighing Indicator T6X
Intrinsically safe indicator for explosive atmospheres
An all-stainless intrinsically safe indicator for static weighing systems with up to four 350 Ω load cells. Suitable for most explosive gas atmospheres.
- Intrinsically safe Ex ib IIC T4 Gb; explosion-proof certificate GYB22.2935X
- All-stainless housing for hostile chemical environments
- RS232 / RS485 / MODBUS-RTU for connection to control systems
- Tare, clear, motion detection and automatic zero tracking
T6X
Product photography for this model is being prepared. Specification is confirmed below.
- Capacity: Supports 4 × 350 Ω load cells
- Accuracy / division: Display 100,000; 6-range; A/D rate 200 Hz / 100 Hz; excitation 5 V; input -10 to 30 mV; operating temperature -10 to 40 °C
- Ingress protection: IP65
Specification
| Material | 304 stainless steel housing |
|---|---|
| Capacity | Supports 4 × 350 Ω load cells |
| Accuracy / division | Display 100,000; 6-range; A/D rate 200 Hz / 100 Hz; excitation 5 V; input -10 to 30 mV; operating temperature -10 to 40 °C |
| Power supply | 9 VDC input, 3 W total; supplied with an intrinsically safe rechargeable battery pack |
| Ingress protection | IP65 |
| Interface / output | RS232 / RS485 / MODBUS-RTU |
| Certification | Explosion protection Ex ib IIC T4 Gb. 2024 catalogue states certificate no. GYB22.2935X; the instrument selection manual states SITIIAS certification — issuing bodies differ between documents, please confirm against the certificate |
| Minimum order | 5 units (OEM branding: 50 units) |
| Lead time | 5-7 days from stock; 10-14 days production |
Where it is used
- Bench, platform and ground-level scales using up to four 350 Ω load cells
- Most explosive gas atmospheres
Ordering this model
- 5 units for a standard order; OEM branding starts at 50 units.
- Stocked products ship in 5-7 days; production orders take 10-14 days.
- Dimensions, material and capacity can be customised. Standard customisation is free of charge; if special drawings are required a sample fee may apply.
- Metal structural parts of the scale body carry no warranty. Electronic products such as load cells and indicators are warranted for one year against non-human damage.
Request a quotation
Send us your capacity, platform size and indicator requirements. We reply with pricing, lead time and packing details.